ONLINE GAS DETECTOR WITH INTERNAL PUMP
YT-95H-B online gas detector series is with built-in pump and suction com-posite gas detector, which can continuously monitor various gas concentrations in environment and pipelines 24 hours on line, display concentration on site and alarm, output standard signals, and transmit data remotely.
It’s the first built-in pump-mounted fixed gas detector in world, with built-in constant flow and large suction pump, the detection accuracy is very high, and the reaction speed is 2.5 times faster than the diffusion model on the market. When the target detected gas is lighter than air, no need to install at high place, which can get the detection results quickly.
Contact szyuante@hotmail.com for more information.
Accurate and fast response
Built-in constant flow and large suction pump, the detection accuracy is very high, and the reaction speed is 2.5 times faster than the diffusion model on the market. When the target detected gas is lighter than air, no need to install at high height place, which can get the detection results quickly.
Easy maintenance
The air chamber module digitizes the analog signal, no need to disassemble the whole machine, just plug and unplug the air chamber part, and then return to the factory for maintenance calibration. It is no longer necessary to disassem-ble the whole machine and return to the factory for replacement sensor like traditional models, so that the replacement of the sensor is as simple and convenient as replacing a light bulb3. The air chamber module digitizes the analog signal, no need to disassemble the whole machine, just plug and unplug the air chamber part, and then return to the factory for maintenance calibration. It is no longer necessary to disassem-ble the whole machine and return to the factory for replacement sensor like traditional models, so that the replacement of the sensor is as simple and convenient as replacing a light bulb
Comprehensive functions
Monitoring the gas concentration in the environment or in the pipeline1. Monitoring the gas concentration in the environment or in the pipeline
Can display the gas concentration unit, ppm, mg / m3 can switched by one-button , the gas concentration value is automatically converted by the system
With full software automatic verification function and zero calibration function, making gas monitoring more accurate and more reliable
infrared remote control function and button function are two-pronged
standard 4-20mA current signal, RS485 digital signal, 1 set of relay signal output, optional 2 sets of relay signals
Optional GPRS wireless transmission function, provide SMS reminder function
Optional built-in wireless module to upload data to the EPA platform or other platforms, and transmit signals without distance limitation
Optional large capacity 8G SD card storage function, storage data can be saved for more than one year
For the harsh detection environment like high temperature, high humidity and high dust areas, there is optional pretreatment system for cooling, dehumidifying,dust removal, protecting the service life of the instru-ment
Free from strong magnetic interference
Can resist strong magnetic interference. Data is guaranteed to be stable and reliable in areas with strong magnetic products or densely populated areas such as tunnels, mines and confined spaces.4. can resist strong magnetic interference. Data is guaranteed to be stable and reliable in areas with strong magnetic products or densely populated areas such as tunnels, mines and confined spaces.
Multilayer filtration system
The instrument has three layers of filtering devices to efficiently filter oil, water, dust and other impurities. Even in the most demanding industrial envi-ronment, the test results can still be trusted.
Application
confined space, research and high standard test environment,
Complex environment of multiple gases
Product Type | Fixed Pump Suction Gas Detector |
Detected gas | various toxic and harmful gases |
Sampling method | built-in pumping type, flow rate 400-500mL/min |
Detection principle | electrochemistry, PID photo ion, catalytic combustion, infrared Ray |
Measure range | 0-1ppm, 0-10ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm (range optional) |
Resolution | 0.001ppm, 0.01ppm, 0.1ppm, 1ppm (related to the selected range) |
Precision | 2% F.S |
Response time | ≤ 8 seconds (T90) |
Installation method | wall-mounted, ducted, circulating (related to the monitoring environment) |
Display | 2.4 inch color display, resolution 320*240 |
Concentration unit | PPM, mg/m3, %LEL, %VOL, etc. can be switched by one button, and the concentration value is automatically converted by the system. |
Interface display | gas molecular formula, concentration unit, measured value, pump status, etc.
Temperature and humidity detection: temperature: -20-50 ° C, resolution: 0.1 ° C; humidity: 0-99% RH, resolution: 1% RH (optional) |
Signal output | standard 4-20mA current signal, RS485 digital signal, 1 group relay signal output; 1-5V (optional), two sets of relays (optional) |
Wireless output (optional) | GPRS wireless transmission function (optional); SMS reminder function (optional); built-in DTU module, upload data to the government’s major monitoring cloud platforms, such as the Environmental Protection Agency, the Safety Supervision Bureau and other platforms, transmission Signal is not limited by distance (optional) |
Data storage | independent SD memory card, record can be saved automatically, customizable recording interval (optional) |
Communication and data download | TXT file of stored data can be download by connecting to the computer directly via USB; with the PC software to download, store, analyze and print the data. |
Power supply | 12-36V DC |
Language | Chinese / English |
Alarm mode | sound and light alarm, high and low alarm value can be set |
Alarm information push | can use WeChat to view real-time data and alarm information push (optional) |
Recovery time | ≤10S |
Working temperature | -20 ° C – 50 ° C (overheating optional filter or pretreatment system) |
Operating humidity | 0 to 95% RH (no condensation) (high humidity can be optionally equipped with filter or pretreatment system) |
Explosion-proof grade | ExdIICT6 Gb |
Protection level | IP65 |
Dimensions | (H x W x D) 320*210*110mm |
Weight | about 3Kg |
Standard accessories | remote controller, instruction manual, qualification certificate, warranty card |
Optional accessories | dry filter, high temperature probe, pretreatment system, controller, power adapter, switching power supply, etc. |
Certificate | type approval certificate for measuring instruments, explosion-proof certificate, CE ,ISO9001 |
Gas | Range | Other available range | Resolution |
CO | 0-1000ppm | 0-100ppm, 0-500ppm, 0-2000ppm, 0-5000ppm, 0-10000ppm | 0.1ppm, 1ppm |
H2S | 0-100ppm | 0-10ppm, 0-50ppm, 0-500ppm, 0-1000ppm, 0-10000ppm | 0.01, 0.1, 1ppm |
O2 | 0-30%VOL | 0-5%VOL, 0-25%VOL, 0-50%VOL, 0-100%VOL | 0.01%VOL |
EX / CH4 | 0-100%LEL | 0-100%VOL | 1%LEL, 0.01%VOL |
N2 | 0-100%VOL | 0.01%VOL | |
NH3 | 0-100ppm | 0-50ppm, 0-500ppm, 0-1000ppm, 0-5000ppm | 0.01, 0.1, 1ppm |
CL2 | 0-10ppm | 0-20ppm, 0-50ppm, 0-100ppm, 0-200ppm, 0-500ppm | 0.01. 0.1ppm |
H2 | 0-1000ppm | 0-100%LEL, 0-2000ppm, 0-10000ppm, 0-40000ppm, 0-4%VOL | 1%LEL, 1ppm |
CH2O | 0-10ppm | 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm | 0.01, 0.1, 1ppm |
O3 | 0-50ppm | 0-1ppm, 0-10ppm, 0-20ppm, 0-100ppm, 0-500ppm, 0-1000ppm | 0.01, 0.1, 1ppm |
CO2 | 0-5000ppm | 0-2000ppm, 0-10000ppm, 0-20000ppm, 0-50000ppm, 0-5%VOL, 0-10%VOL, 0-50%VOL, 0-100%VOL | 1ppm, 0.01%vol |
NO | 0-100ppm | 0-20ppm, 0-50ppm, 0-500ppm, 0-1000ppm, 0-4000ppm | 0.01, 0.1, 1ppm |
NO2 | 0-20ppm | 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-4000ppm | 0.01, 0.1, 1ppm |
NOX | 0-20ppm | 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-4000ppm | 0.01, 0.1, 1ppm |
SO2 | 0-10ppm | 0-20ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-2000ppm | 0.01, 0.1, 1ppm |
ETO | 0-10ppm | 0-20ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm | 0.01, 0.1, 1ppm |
PH3 | 0-10ppm | 0-20ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-5000ppm | 0.01, 0.1, 1ppm |
HCL | 0-10ppm | 0-20ppm, 0-50ppm, 0-100ppm | 0.01ppm |
HCN | 0-10ppm | 0-20ppm, 0-50ppm, 0-100ppm | 0.01ppm |
COCL2 | 0-1ppm | 0.01ppm | |
CLO2 | 0-10ppm | 0-20ppm, 0-50ppm, 0-100ppm | 0.01ppm |
SiH4 | 0-10ppm | 0-50ppm | 0.01ppm |
F2 | 0-10ppm | 0-1ppm | 0.01ppm |
HF | 0-10ppm | 0.01ppm | |
HBr | 0-10ppm | 0-50ppm, 0-100ppm | 0.01ppm |
H2O2 | 0-100ppm | 0-500ppm, 0-1000ppm, 0-2000ppm | 0.01, 0.1, 1ppm |
B2H6 | 0-5ppm | 0-10ppm | 0.01ppm |
AsH3 | 0-1ppm | 0-10ppm, 0-50ppm | 0.01ppm |
GeH4 | 0-1ppm | 0.01ppm | |
N2H4 | 0-1ppm | 0.01ppm | |
THT | 0-100ppm | 0-50mg/m3, 0-100mg/m3 | 0.01ppm, 0.01mg/m3 |
Br2 | 0-5ppm | 0-10ppm, 0-50ppm | 0.01ppm |
C2H2 | 0-100ppm | 0-2.3%VOL | 0.01ppm, 0.01%VOL |
C2H4 | 0-10ppm | 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 2.4%VOL | 0.01, 0.1, 1ppm, 0.01%VOL |
CH3OH | 0-100ppm | 0-50ppm, 0-500ppm, 0-1000ppm | 0.01, 0.1, 1ppm |
C2H5OH | 0-100ppm | 0-50ppm, 0-500ppm, 0-1000ppm | 0.01, 0.1, 1ppm |
CH4S | 0-100ppm | 0.01ppm | |
C8H8 | 0-10ppm | 0-50ppm, 0-100ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm | 0.01, 0.1, 1ppm |
C4H6 | 0-10ppm | 0-50ppm, 0-100ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm | 0.01, 0.1, 1ppm |
VOC/TVOC | 0-10ppm | 0-1ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm | 0.001, 0.01, 0.1, 1ppm |
CH3Br | 0-10ppm | 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm | 0.001, 0.01, 0.1, 1ppm |
C6H6 | 0-10ppm | 0-1ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm | 0.001, 0.01, 0.1, 1ppm |
C7H8 | 0-10ppm | 0-1ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm | 0.001, 0.01, 0.1, 1ppm |
C8H10 | 0-10ppm | 0-1ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-5000ppm, 0-10000ppm | 0.001, 0.01, 0.1, 1ppm |
For other gases and measure range are not listed, please contact us for free quote and information.
Filter-to filter the dust and vapour
Drying cylinder-Lower down the humidity and applicated in the high humidity temperature
High Temperature probe SA-Lower down the temperature in 100 ℃
High Temperature probe SB- 2 TYPES for option. Can lower down the temperature in 600 ℃ or 1200℃